User's Manual
netAqua
TM
USER MANUAL Roslen Eco-Networking Products
v1.0.03 © 2014 by Roslen Eco-Networking Products. All rights reserved Page 46 of 59
• Hold ENTER to change.
The general arrangement of the Main Control page data follows the concept shown in Figure 34.
Main Control Page
Hold ENTER to change
Global Watering: Enabled
Figure 34: Main Control Page
The Hold ENTER to change function is a special case of programming. When the user holds the ENTER
pushbutton switch for two seconds, the Global Watering enable status toggles between Enabled and
Disabled.
When there is no user pushbutton switch activity for 2 minutes after the user has navigated to a page
different from the Main Control page, the LCD reverts to the Main Control page.
3.9.3.2. Watering Status Page
The Watering Status page contains the following information:
• Currently Watering status: Yes or No
• Currently watering cycle and zone, plus active or break phase for slope control
• Last Cycle: days, hours, minutes
• Next Cycle: days, hours, minutes.
The time is displayed in either AM/PM or 24-hour designations, depending on the time format setting in
the Browser Interface.
The general arrangement of the Watering Status page data follows the concept shown in Figure 35.
Watering Status
Last Cycle: 00d, 01h, 02m
Next Cycle: 01d, 22h, 58m
Currently Watering: NO
Figure 35: Watering Status Page
3.9.3.3. System Status Page
The System Status page contains select system level configuration information:
• Date: Day, Month, Year Time: HH:MM
• IP Address of the Ethernet interface
• IP Address of the WiFi interface
• Software version
The time is displayed in either AM/PM or 24-hour designations, depending on the time format setting in
the Browser Interface.
The general arrangement of the System Status page data follows the concept shown in Figure 36.