Specifications
Rosen Aviation 19” HD Widescreen Display
Document Number: 104328
Revision: C
Date: 03/11/14
Template: 4.4.1.6FM2; Revision A; 12/06/12
Page 27 of 34
8.7.2. Constant Switch Mode
Constant enables you to specify the two sources the display will switch between when
the Source Select switch pin #2 (SELECT_SW_IN) goes between the Open state and
Ground state.
Highlight TechnicianSource ModeSource Select and press ENTER.
Select Constant and press ENTER. Press ▼ to select Open and press ENTER.
Select which video input will be in an open state and press ENTER.
Press ▼to select Ground and press ENTER.
Select which video input will be to a ground state and press ENTER.
Select Back to return to the Technician Menu, or press EXIT to exit the OSD.
Figure 31 Source Select Constant options
9. TECHNICAL REFERENCES AND SUPPORT
Always check www.rosenaviation.com under the Products tab to
ensure that you are working with the most current revision of
technical documentation.
Table 3 Technical references
Product
Part Number
Location
Universal Color Remote Control
Contact Rosen Sales for part number availability
RS-232 7-button External Controller
0300-408
www.rosenaviation.com
If you need assistance in configuring a universal remote control to work with a 19” High-definition
display, please contact Rosen Aviation Technical Support at 541.342.3802.