Specifications

Page 16 Rosen Aviation Displays
Troubleshooting
Troubleshooting
If the monitor does not function properly, refer to the following
troubleshooting table for symptoms and possible solutions
before contacting Rosen field support.
Notes:
Always use an oscilloscope to verify the video signal
Always use a multimeter to verify voltages
Check actual results against the requirements
described in this manual
PROBLEM POSSIBLE SOLUTION
No power Verify that the pinout is correct . Push
and hold the power switch for about one
second.
Verify Monitor is fully inserted into base
receptacle.
No video on Verify that the pinout is correct.
screen
Verify that the video source is on and has
a tape or DVD installed.
Verify video signal at monitor end, Use an
oscilloscope or another monitor.
Screen is Verify that the monitor is getting power
(green LED on) and the pinout is correct.
Verify that the video source is on and has
a tape or DVD installed.
Verify all connections
Screen is blue Verify signal at monitor end, Use an
oscilloscope or another monitor.
Verify that the pinout is correct.
Verify that the video source is on and has
a tape or DVD installed.
black