Specifications

Rosen Aviation Smart Remote Display System
Document Number: 106957
Revision: A
Date: 03/13/14
Template: 4.4.1.6FM2; Revision A; 12/06/12
Page 11 of 24
The RDM receives power, control, and serialized video from the Smart RMEB located up to 50
feet away, as shown below. To obtain information about interconnect cables, please contact
Rosen Aviations Technical Support at 541.434.4512 and request the Interconnect Cable
Specification for Venue System Remote Electronics (P/N 107175).
The peripheral SDI display may be located up to 75 feet away from the Smart RMEB. Please
contact Rockwell Collins for cable specifications.
Figure 8 Smart Remote Display system connections
5.1. Pinout Connections
There are several ways to connect the remote display system to an aircraft’s entertainment
system.
Follow the pinout descriptions on the technical drawing (P/N 0700-150-CD) to assist in
completing the wiring connections.
Note: This display is for entertainment purposes only; connect to a non-critical power bus.
5.2. Address Strapping
The Smart RMEB has different IP addresses based on the platform mode that you set.
5.2.1. Factory Mode
From the factory, the Smart RMEB will have an IP Address set to 10.10.10.50 with a
netmask of 255.255.255.0.
The factory mode IP Address is always hardcoded; therefore, you do not have to set
the address bit pins.
The address bit pins are pins 1 thru 5 on the P2 connector.