ELECTRONIC REVISION CONTROLLED Document Number 106957 Rev A
Rosen Aviation Smart Remote Display System Technical Manual, Smart Remote Display System © 2014 by Rosen Aviation, LLC All Rights Reserved The information contained herein is proprietary to Rosen Aviation, LLC. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form by any means without the written authorization from Rosen Aviation, LLC, except as allowed under copyright laws.
Rosen Aviation Smart Remote Display System Contents 1. INTRODUCTION.............................................................................................................................. 5 1.1. System Overview ...................................................................................................................... 5 1.2. Smart Remote Display System Components ....................................................................... 6 1.2.1. Technical Drawings.............................
Rosen Aviation Smart Remote Display System 8.4. Supported Video Specifications ........................................................................................... 22 8.4.1. HDMI Standard Resolutions ................................................................................................22 8.4.2. 3G-SDI Resolutions .............................................................................................................22 9. DEFINITIONS ..................................................
Rosen Aviation Smart Remote Display System 1. INTRODUCTION The Smart Remote Display System consists of an ultra-thin remote display module (RDM) and a smart, high-definition remote electronics box that can run an extra peripheral SDI display to maximize the viewing experience. The remote electronics design provides more mounting flexibility because the video processing electronics box can be located up to 50 feet from the displays.
Rosen Aviation Smart Remote Display System 1.2. Smart Remote Display System Components Each Smart RMEB will operate one RDM. To complete your RDM installation, the following cosmetic components are also available: Remote Display Modules (RDM) are available in sizes: 19”, 22”, 24”, 26”, 32”, 42”, and 55” Mounting accessories: front bezel, cosmetic back, and credenza lift Connector kits (sold separately) – see the technical drawing for specific part numbers 1.2.1.
Rosen Aviation Smart Remote Display System 2.1. Smart RMEB Configurations The Smart RMEB has several possible operational mode configurations, depending on the specific aircraft installation. The unit has four possible media inputs (HDMI, SDI, Streaming Video over Ethernet, or USB), two possible video outputs (RDM and a peripheral SDI Display), and a single analog audio output for consistent sound quality at any volume. Additionally, the system can play media from the internal solid-state storage drive.
Rosen Aviation Smart Remote Display System 3.1.1. Bulkhead Mounting Requirements The Smart RMEB and RDMs do not require any external forced-air cooling. A flush mounted RDM can mount either from the back, through an interior wall, or from the front mounting tabs. Proud-mounted RDMs must attach from the front into the cosmetic back. Use the technical drawings to assist in the installation process. Pay close attention to the dimensions when considering installation requirements.
Rosen Aviation Smart Remote Display System Attach the 32” cosmetic back to the bulkhead using six #6 100 FHP screws (customer supplied). Attach the 42” cosmetic back to the bulkhead using ten #6 100 FHP screws (customer supplied). Attach the 55” cosmetic back to the bulkhead using twelve #6 100 FHP screws (customer supplied) Attach to bulkhead Attach to RDM Figure 4 3201-800, 4201-800, and 5501-800 cosmetic back mounting bracket 4.2.
Rosen Aviation Smart Remote Display System 4.3. Mounting a Bezel Mount the cosmetic back and monitor before attaching the bezel. To attach a bezel to a RDM, align the mounting bosses with the monitor standoffs and gently press on the retaining clips to snap the bezel into place. Bezels attach around the perimeter of the RDMs with retention fasteners. The quantity and type of bezel fasteners varies depending on the size of the bezel and RDM.
Rosen Aviation Smart Remote Display System The RDM receives power, control, and serialized video from the Smart RMEB located up to 50 feet away, as shown below. To obtain information about interconnect cables, please contact Rosen Aviation’s Technical Support at 541.434.4512 and request the Interconnect Cable Specification for Venue System Remote Electronics (P/N 107175). The peripheral SDI display may be located up to 75 feet away from the Smart RMEB.
Rosen Aviation Smart Remote Display System 5.2.2. Venue Mode The Smart RMEB in the Venue mode has an IP Address of 10.240.11.xx with a netmask of 255.240.0.0. The last octet of the IP address (xx) is calculated on how the address bit pins 1 thru 5 are wired on the P2 Connector. To specify an IP address of 10.240.11.1, wire the address bit pins 1 thru 5 on the Smart RMEB as follows. Table 1 A Smart RMEB IP address of 10.240.11.
Rosen Aviation Smart Remote Display System Up to thirty-two (32) unique IP addresses are available in Venue mode, as shown in Table 3, where 1 = OPEN and 0 = GROUND.
Rosen Aviation Smart Remote Display System 6. INITIAL POWER UP Make sure that power is turned off and connect the following harnesses to the Smart RMEB connectors: 1. Attach secure ground connections on the Smart RMEB housing and monitor chassis grounding lugs. 2. Connect an Ethernet communication harness to P2. Refer to the Smart RMEB Outline and Installation Drawing (P/N 0700-150-CD) for pinout information. 3. Connect 28 VDC power to the Power connector.
Rosen Aviation Smart Remote Display System 7. MAINTENANCE OSD MENU Note: Depending on the installation, the Maintenance OSD Menu may not be visible in the application. An interactive, on-screen display (OSD) menu for managing certain video settings on the RDM is accessible through the Maintenance Mode of the Rockwell Collins’ application software. There are two pages of OSD options, and you access the second page by selecting the Advanced option, as shown below.
Rosen Aviation Smart Remote Display System 7.2. Backlight To adjust the intensity of the RDM’s backlight, select Backlight to open the control bar, as shown in Figure 12. The adjustment range for the Backlight value is 0 to 100. Figure 12 Backlight control bar 7.3. Hue To adjust the tint or color shades of the RDM’s screen, select Hue to open the control bar, as shown in Figure 13. The adjustment range for the Hue level is 0 to 360. Figure 13 Hue control bar 7.4.
Rosen Aviation Smart Remote Display System CINEMA: Expands the source video in the vertical and horizontal dimensions to fill the display screen. Letterbox-format DVDs will have small or no bars showing in this mode, while 4:3 aspect video sources will expand beyond the screen boundaries, appearing cropped. 7.5. Advanced Menu The Advanced menu contains a second page of OSD video settings to fine-tune the primary screen colors, picture position, overscan, and to restore the RDM’s factory screen settings.
Rosen Aviation Smart Remote Display System 7.5.2. Horizontal and Vertical Adjustments The Horizontal/Vertical Scale and Position settings enable you to shift the picture’s position to fill the screen. The Scale settings enable stretching/cropping an image and the Position settings enable you to shift the image horizontally or vertically, thus minimizing or eliminating the black bars at the edge of the picture. Select the Advanced and then choose an adjustment option.
Rosen Aviation Smart Remote Display System 8. TECHNICAL REFERENCES AND SUPPORT Always check the Rosen Aviation website under the Products tab to ensure that you are working with the most current revision of technical documentation. 8.1. Troubleshooting If the display does not function properly, refer to the following troubleshooting table for symptoms and possible solutions before contacting Rosen Technical Support. Note: Always use a multimeter to verify voltages.
Rosen Aviation Smart Remote Display System Table 5 Part numbers referenced in the manual Product Part Number Location Smart RMEB Outline & Installation Drawing 0700-150 0700-150-CD Contact Rosen Technical Support Smart RMEB Rockwell DEU - 310 441-2028-100 Contact Rockwell Collins’ Customer Support 107175 Contact Rosen Technical Support Interconnect Cable Specification for Venue System Remote Electronics 8.2.
Rosen Aviation Smart Remote Display System Description Vibration Random Vibration – Fixed Wing Aircraft Magnetic Effect Magnetic Effect Power Input Normal Operating Conditions (DC) Section Category 8 8.5.2 S (Curve B) 15 15.3 A 16 16.6.1 Average Value Voltage (DC) 16.6.1.1 Z Ripple Voltage (DC) 16.6.1.2 Z Momentary Power Interruptions (DC) 16.6.1.3 Z (A) Normal Surge Voltage (DC) 16.6.1.4 Z Engine Starting Under Voltage Operation (DC) 16.6.1.5 Z Abnormal Operating Conditions 16.6.
Rosen Aviation Smart Remote Display System Description Emission of Radio Frequency Energy Section Category 21 Conducted RF Emission 21.4 M Radiated RF Emission 21.5 M Electrostatic Discharge (ESD) Electrostatic Discharge (ESD) Flammability Comments 25 25.5 A 26 N/A Flammability testing in accordance with 14 CFR 25.853 Appendix F 8.3.1. Other Certification Considerations for RDMs Description Comments Static Abuse Load (300 lbs.) Testing in accordance with DO-313 section 4.
Rosen Aviation Smart Remote Display System 9. DEFINITIONS 3G-SDI Newer, high-definition serial digital interface with a single 2.
Rosen Aviation Smart Remote Display System VGA Video Graphics Array Vpp Volts peak-to-peak W Watts 10. REVISION HISTORY Revision E is limited to draft or prototype documents. Revisions I, O, Q, S, X and Z are not to be used. Revision Date A 03/13/14 Document Number: 106957 Template: 4.4.1.