Specifications
Rosen Aviation Remote Display System
Document Number: 105134
Revision: A
Date: 08/08/11
Template: 4.2.3-6-FM; Revision A; 16 May, 2005
Page 8 of 39
3.1. RDM Mounting Options
The remote monitors are designed for vertical wall/bulkhead mount applications. They can be
flush mounted from the back, through an interior wall, or from the front mounting tabs. Proud
mounted RDMs must be mounted from the front into the cosmetic back.
Minimum fasteners required four 8-32 or eight 4-40; torqued to 7 ± 1 in-lbs.
Maximum projection of screws into the 19” & 26” flush mount rear chassis is ¼”
Maximum projection of screws into the 24” flush mount rear chassis is 3/8”
A minimum of ½” clearance for the top and bottom vents or ½” clearance to the entire
back is required.
The manual groups monitors by size. Outline and Installation drawings are available on Rosen’s
website www.rosenaviation.com to assist in the installation process. Pay close attention to the
dimensions when considering installation requirements. Dimensions for some models may vary,
so be sure to consult the latest drawings on Rosen’s website for more information.
Touching the LCD with excessive force may leave pressure spots
that show in video display. Handle with care.
3.1.1. 19-inch RDMs
The following figures show the general dimensions for the 19” RDM mounting options.
Figure 3 Rear view of a 19” flush mount
Use a minimum
pattern of four
mounting points
#8-32 hardware