Specifications
Rosen Aviation Remote Display System
Document Number: 105134
Revision: A
Date: 08/08/11
Template: 4.2.3-6-FM; Revision A; 16 May, 2005
Page 29 of 39
8.2. Power Mode
Use Power Mode to set display’s on/off state.
From the Technician Menu, press the ▼ button to select Power Mode and then press ENTER.
Use the ▲▼ buttons to set the option and then press ENTER.
Options include the following:
Auto-On: The display always starts up in the ON state when 28V is applied (default).
Auto-Off: The display always starts up in the standby state when 28V is applied.
Restore Previous: The display returns to the previous power settings after any power
interruption.
Ground-On: The display always starts up in the ON state when the power pin is
grounded, and ignores all power commands from the IR, RS-232, and RS-485. This
setting will not take effect until you close the OSD.
Open-On: The display always starts up in the ON state when the power pin is open
(not grounded), and ignores all power commands from the IR, RS-232, and RS-485.
This setting will not take effect until you close the OSD.
Momentary: The LCD power will toggle between on and off after the external power
discrete is momentarily grounded.
Select Back to return to the Technician Menu.
Press EXIT to exit the OSD.
8.3. OSD Timeout
Use OSD Timeout to set the amount of time the menu screens and control bars are visible,
without making any changes, before they timeout and close automatically.
There are three increments: 6 Seconds, 15 Seconds, and 30 Seconds.
From the Technician Menu, press the ▼ button to select OSD Timeout and then press ENTER.
Use the ▲▼ buttons to select a time increment and press ENTER.
Press EXIT to exit the OSD.
8.4. Network ID
Use this option to specify the IR and RS485 network addresses to control multiple displays from
a single cabin management system or remote. For example, the monitor ID numbers on the
Pronto remote correspond to the Network ID.
Each display requires a unique address on the RS-485 network. Setting this address sets the
value for both interfaces. Network settings for Rosen displays are scaled from 1 to 31.
From the Technician Menu, press the ▼ button to select the Network ID, and then press
ENTER to open the screen.
Use the ▲▼ buttons to select an address between 1 and 31 for the display and press ENTER.
Press EXIT to exit the OSD.