4. SYSTEM CONNECTIONS
The RDM receives power, control, and serialized video from the RMEB via connectors P3 and P4
on the RMEB from up to 50 feet away, as shown below. The RMEB outputs a serialized video
signal via CAT6 cable from P4 and provides conditioned power and control to the RDM via a
harness with DB15 connectors from P3. We suggest using shielded harnesses to improve EMI
performance. See the wiring tables on the Outline & Installation drawings for details.
Figure 13 Remote display system connections
4.1. Remote Electronics Box Connectors
This section describes the RMEB connectors and their corresponding functions. All of these
video inputs are functional on the 0700-104 RMEB; however, the inputs available vary by model.
Figure 14 RMEB connectors
Table 1 RMEB connectors and functions
Connector
Function
P1
Communication for RS-232, RS-485, External IR control
P2
Power in / Ethernet in
P3
Conditioned power out to the monitor
P4
Video signal out to the monitor
3G SDI 1 & 2
3G SDI video in
DVI-I 1 & 2
HDMI / DVI / Component / RGB video in
CVBS 1 & 2
Composite video in