Specifications
Rosen Aviation Remote Display System
Document Number: 105134
Revision: A
Date: 08/08/11
Template: 4.2.3-6-FM; Revision A; 16 May, 2005
Page 12 of 39
Figure 10 Front view of a 26” flush or semi-proud mount from the front tabs
3.2. Cooling and Ventilation
Do not block the side fans on the RMEB. The fan openings require a minimum of 4 square
inches of free air ventilation – 2 square inches per side.
The RDMs do not require any external forced-air cooling.
Venting: The RDMs require 4.7 square inches of ventilation top and bottom. The
area may be split, continuous, or at either end of the unit.
Clearance: The RDMs require a minimum of ½ inch of clearance for the top and
bottom vents or ½” clearance to the entire back of the unit.
Four mounting
tabs with two
screws each
4-40 FHP
screws