Reference Manual

Device Variable Index
March 2016
Reference Manual
00809-0100-4045, Rev AB
61
Device Variable Index
Appendix E Device Variable Index
This section outlines the most important alerts in the HART
®
command 48 additional status
field for Rosemount
Wireless Pressure Gauge. The information in this section can be used
by DeltaV
for notification monitoring, and in the Emerson Smart Wireless Gateways for
additional status mapping in Modbus
®
, OPC, etc.
E.1 Messages and descriptions
A complete list of additional status bits is available in the Gateway.
Tab le E- 2 to Ta bl e E -4 shows a list of the most important messages that may be displayed.
Table E-2. Failures
Table E-1. Device Variables
Device variable Index
0 Supply voltage
1Pressure
2Custom
3 Sensor temperature
Message
Additional
status
(1)
1. Location of the alert in the HART command 48 Additional Status field.
Description
Radio failure Byte 12 :: Bit 4
Wireless radio has detected a failure or stopped
communicating
Configuration alert Byte 2 :: Bit 6 Device has detected a configuration error
Over-pressure seen Byte 4 :: Bit 0
Pressure has gone beyond the maximum
operating limits of the device, which may have
caused permanent damage to the sensor
Critical power failure Byte 6 :: Bit 2
Supply voltage is too low for the device to
broadcast updates
Electronics failure Byte 8 :: Bit 6
Electronics error that could impact the device
measurement reading has occurred
Dial failure Byte 4 :: Bit 4
Device has detected a failure or unable to confirm
dial location