Reference Manual

43
Specifications and Reference Data
Specifications and Reference Data
March 2016
Reference Manual
00809-0100-4045, Rev AB
A.2.13 Output
IEC 62591 (WirelessHART), 2.4 GHz DSSS
A.2.14 Wireless radio (internal antenna)
Frequency: 2.400 – 2.480 GHz
Channels: 15
Modulation: IEEE 802.15.4 compliant DSSS
Transmission: Maximum of 10 dBm EIRP
Integrated omni-directional antenna
A.2.15 Wireless update rate
Wireless update rate is user-selectable from one minute to
60 minutes and is separate from local display.When wireless
is activated, the update rate defaults to once a minute.
A.2.16 Vibration effect
No significant effect when tested per IEC60770-1 or ASME
B40.1 requirements
IEC60770-1 high vibration level - field or pipeline: 10-60 Hz
0.21 mm displacement peak amplitude/60-2000 Hz 3 g
A.2.17 Dial update rate
Dial update rate is user-selectable for four seconds or two
seconds and is separate from the wireless update rate.
Factory default is four seconds.
A.3 Wireless connectivity out-of-the-box
A.4 Spare parts
Products in order
Network ID & Join Key
are generated
Wireless connectivity
out of the box
Rosemount Wireless Pressure Gauge Automatically Manual activation required
Rosemount Wireless Pressure Gauge Customer specified Activated
Rosemount Wireless Pressure Gauge and
Emerson Smart Wireless Gateway
Automatically (matching) Manual activation required
Description Part number
Battery 00G45-9000-0001
Battery retainer 00G45-9000-0002
Screws for retainer and shroud 00G45-9000-0003
Cover assembly
(inlcudes cover and O-ring)
00G45-9001-0001
Cover O-ring 00G45-9001-0002