Reference Manual
23
Reference Manual
00809-0100-4045, Rev AB
Configuration
March 2016
Configuration
Table 3-2 contains further information on device specific MWP as it correlates to the device
specific scale range.
Table 3-3 demonstrates the different dial locations based on configuration of the
overpressure notification (Unlatched vs Latched).
Table 3-2. Maximum Working Pressure
Scale range
Maximum working
pressure (MWP)
105% of MWP
Maximum
overpressure limit
Vacuum to 30 psi 30 psi 31.5 psi 750 psi
31 – 150 psi 150 psi 157.5 psi 1,500 psi
151 – 800 psi 800 psi 840 psi 1,600 psi
801 – 4,000 psi 4,000 psi 4,200 psi 6,000 psi
Table 3-3. Dial Locations
Measured process
pressure
Parameter configuration
Unlatched (factory default) Latched
Within scale range
LED Color: Green
Dial Location: On-Scale
LED Color: Green
Dial Location: On-Scale
Beyond scale range
and <105% of MWP
LED Color: Green
Dial Location: Off-scale
LED Color: Green
Dial Location: Off-scale