2051 Wireless pressure transmitter, damping only takes effect when the device is placed in high
power refresh mode and during calibration. In normal power mode, the effective damping is 0.
Note that when the device is in high power refresh mode, battery power will be depleted rapidly.
Determine the appropriate damp setting based on the necessary response time, signal stability,
and other requirements of the loop dynamics of your system. The damping value of your device
is user selectable from 0 to 60 seconds.
DampingwithaFieldCommunicator
From the HOMEscreen, enter the fast key sequence
Enter desired Damping Value and select APPLY.
DampingwithAMSDeviceManager
Right click on the device and select Configure.
1.
Select
ManualSetup
.
2.
Within the PressureSetupbox, enter desired damping value and click Send.
3.
Carefully read the warning and click Yesif it is safe to apply the changes.
2.9.3
Write protect
The Rosemount 2051 Wireless pressure transmitter has a software write protect security
feature.
EnablingwriteprotectwithaFieldCommunicator
From the HOMEscreen, enter the fast key sequence
Select WriteProtectto enable.
EnablingwriteprotectwithAMSDeviceManager
Right click on device and select Configure.
1.
Select
ManualSetup.
2.
Select the tab labeled DeviceInformation.
3.
Select WriteProtectto enable this feature.
2.10
Diagnosticsandservice
Diagnostics and service functions listed below are primarily for use after field installation. The
Transmitter Test feature is designed to verify that the transmitter is operating properly, and can
be performed either on the bench or in the field.
DeviceDashboardFastKeys
2, 2, 7, 1
DeviceDashboardFastKeys
2, 2, 2, 4