Owner's manual

SIGNAL
AIR
SUPPLY
AIR
Figure 1-3. Typical Power Positioner Installation
1-4. MODEL PP405TR SPECXFICATIONS. Model
PP405TR Power Positioner specifications, Table 1-2,
contains information about power positioner operating
characteristics. Use Table l-2 to make sure that
available conditions are suitable for power positioner
before choosing mounting location.
l-5. STORAGE INSTRUCTIONS. Use the following
guidelines for power positioner storage.
a. Storage Environment. Store power positioner in
a warehouse environment that maintains the
following conditions:
1. Ambient temperatures above 45°F (7°C).
2. Humidity below 80% RH.
b. Power Positioner Preparation for Storage.
WARNING
Keep Tectyl 506 away from beat, sparks,
and open flames. Use with adequate
ventilation to cure and to prevent an
I
explosive atmosphere from for&g.
CAUTION
Use only approved thinning methods when
applying rust-preventive compounds. Do not
apply heat to compound. Fire or explosion
may result. Refer to manufacture of rust-
preventive compound for specific
application, thinning, clean-up and removal
instructions.
Coat all non-painted surfaces and exposed metal
with a rust-preventive compound (Tectyl 506 or
a comparable substitute). If not using Tectyl506,
compare substitute with specifications for Tectyl
506 (Table 1-3. Specifications for Recommended
Rust Preventive Compound).
Table 1-3. Specilkations for Recommended Rust
F’reventive Compound.
REQUIREMENTS PROPERTIES
Approximate air dry time
1 hour
Low Temperature Flexibility (90” bend with
no flaking or cracking) -10°F (-22S”C)
Volatile Organic
Content (V.O.C.)
3.24 lbs/U.S. Gallon
400 grams/Iiter
Accelerated Corrosion Tests: (5% Salt Spray (Hours))
ASTM (see Note 1) B-117 at 1.3 mils (2 x 4 x
l/8 inch Polished Steel Panels)
2OlXl
DIN (see Note 2) 50021 at 32.5 microns
(125 x 200 mm DIN 1623 Panels)
168
NOTES: (1) ASTM (American Society for Testing and
Materials)
(2) DIN (Deutsche Industrie Normen)
c. Storage Preventive Maintenance. If storing
power positioner for more than six months, use
the following preventive maintenance guidelines.
1. Cycle cylinder and piston, either manually or
by air, every 6 months.
2. Perform General Cleaning and Lubrication
(paragraph 6.3). and Cylinder and Piston,
Cleaning and Lubrication (paragraph 6-7).
before installing power positioner.