Instruction manual
Orion XC Installation and Operations Manual
31
Access Control
The access control configuration is set in this screen. The screen can be accessed in the OSD and the
Java Tool.
The following settings can be modified.
Field Selection Description
Activated
Users must login with a user name and a password once to
enter OSD. Thereafter the user remains logged in until he
explicitly logs out or an auto logout is affected.
Note: When using the Force User Login function, console
favorites and console macros remain active.
Force User Login
Deactivated Function not active (default)
Activated
CPU access is restricted according to the permissions in the
User ACL (Access Control List).
User login is required.
Switching by keyboard 'Hot Keys' requires a prior login.
Enable User ACL
Deactivated Function not active (default)
Activated
CPU access is restricted according to the permissions in the
respective Console ACL (Access Control List). No login
required.
Enable Console
ACL
Deactivated Function not active (default)
Activated Newly created users automatically receive access to all CPUs.
Enable new User
Deactivated Function not active (default)
Activated
Newly created CON devices automatically receive access to
all CPUs.
Enable new CON
Deactivated Function not active (default)
Activated
The console will be automatically disconnected from any
current CPU connection when the OSD is opened.
Auto Disconnect
Deactivated Function not active (default)
OSD Timeout
0-999 seconds
Period of inactivity after which OSD will be closed
automatically.
Select 0 seconds, for no timeout (default: 0 seconds)
Auto Logout
0-999 minutes
Period of inactivity of a logged-in user at a console after which
the user will be automatically logged out. The user’s current
connection may be disconnected as a result of the logout,
depending on the defined rights in the User and Console ACL.
Select 0 minutes to disable inactivity logout.
Using the setting -1 allows the user to remain logged in until
a manual logout is executed.
The timer is not active as long as the OSD is open.
(default: 0 minutes)