Instruction manual
Orion XC Installation and Operations Manual
109
Trace Function
All events, e.g. activities and switching operations of the Orion XC matrix, are logged and displayed in this
screen. This function is used for diagnostic purposes. This screen can only be accessed from the OSD.
The following information is shown in this menu:
Field Description
Date
Date stamp
Time
Time stamp
Message
Detailed description of the event
Trace Options
Select Status > Trace IO Board in the main menu to check the events on the current I/O board.
Select Status > Trace Matrix to check the matrix events.
Syslog Monitoring
Logging of the Orion XC matrix activities, including switching operations and the performance of function
critical components like fans or power supply units, is done in this screen. It can only be accessed from
the Java Tool.
To start Syslog Monitoring proceed as follows.
Select the Matrix->Monitoring in the menu bar, or click the Monitoring icon in the tool bar.
Figure 107. Syslog Monitoring with the Java Tool
The logging of system activities starts when the Monitoring menu is opened, and remains active until the
tab is closed.
Note: Syslog messages are transmitted by UDP. This uses port 514, which should not be blocked by a
firewall.
During logging, the activities are written continuously into logging files and stored locally. This logging
process includes a number of options as described below.