Instruction manual
46
Orion Installation and Operations Manual
Telegrams, Switching functions Switch Matrix
No
Function
Telegram
Reply
11 Set Switch Matrix (Complete Setup):
• requires 48 values (first 16 CPU’s,
then 32 CON Ports)
• 0x80 for “No Output“
• CON01…CON16
Output Signal from
CPU#1…CPU#16
(cf. Telegram 3)
• CPU01…CPU32
Output Signal from
CON#1…CON#32
(cf. Telegram 7)
Attention: Correct
assignment to be
ensured by user!
Attention: only 16
CON Ports available,
requires 16x 0x80!
STX, 0x51,
<CPU#1>,
<CPU#2>,
…,
<CPU#16>,
<CON#1>,
<CON#2>,
…,
<CON#32>,
ETX
ACK, ECHO
12 Reset Switch Matrix STX, 0X52, ETX ACK
13 Report Switch Matrix
(Complete Setup)
• Output of 48 values
• 0x80 for
„No Output“
• The first 16 values
describe CON Port
Output
(cf. Telegram 3)
• The next 32 values
describe the CPUOutput
(cf. Telegram 7)
STX, 0x53, ETX STX, 0x53,
<CPU#1>,
<CPU#2>,
…,
<CPU#16>,
<CON#1>,
<CON#2>,
…,
<CON#32>,
ETX
Save / Load Switch
Matrix
14 Save Matrix
Configuration to Flash
STX, 0x66, 0x8C,
<Config File No >,
ETX
ACK
15 Load Matrix
Configuration from
Flash
STX, 0x67, 0x8C,
<Config File No >,
ETX
ACK, ECHO
(contains
Complete Setup)
Assignment of Configuration Files to Telegram
Configuration Files Config File No
Configuration Files Config File No
Default.sys 0x80
Config05.sys 0x85
Config01.sys 0x81
Config06.sys 0x86
Config02.sys 0x82
Config07.sys 0x87
Config03.sys 0x83
Config08.sys 0x88
Config04.sys 0x84