Installation interfaces ROPOX KITCHEN PRODUCTS PDF 6139 / 02.03.
Contents CONTENTS ....................................................................................................................................................... 2 ROPOX DIAGONAL .......................................................................................................................................... 3 ROPOX VERTI ELECTRIC ............................................................................................................................... 4 ROPOX VERTI-INSIDE ..............
Ropox Diagonal Cabinet width 40-180 cm / 15,7 – 70,8 in (30-40904 to 30-40918) Assumptions for schematic diagram: Cabinet height = 704 mm / 27,7 in – (for other cabinet heights the dimension sketch will be changed accordingly) Construction – see dimensions on the following page Minimum area for reinforcement of wall. Wall material must be suitable for screw mounting. Area for electric installation. (The frame is designed for cabinet heights from 704-920 mm / 27,736,2 in.
Cabinet width 40-50 cm 15,7 – 19,7 in (30-40904 to 30-40905) Cabinet width 60-120 cm 23,6 – 47,2 in (30-40906 to 30-40912) Page 4 Cabinet width 130-180 cm 51,2 – 70,8 in (30-40913 to 30-40918) © ROPOX 2015
Ropox Verti Electric Construction – see dimensions on the following page Cabinet width 40-180 cm / 15,7 – 70,8 in (30-40604 to 30-40618) Minimum area for reinforcement of wall. Wall material must be suitable for screw mounting. Assumptions for schematic diagram: Cabinet height = 704 mm / 27,7 in – (for other cabinet heights the dimension sketch will be changed accordingly) Area for electric installation. Area for conduit. (The frame is designed for cabinet heights from 704-920 mm / 27,736,2 in.
Cabinet width 40-50 cm 15,7 – 19,7 in (30-40604 to 30-40605) Cabinet width 60-120 cm 23,6 – 47,2 in (30-40606 to 30-40612) Page 6 Cabinet width 130-180 cm 51,2 – 70,8 in (30-40613 to 30-40618) © ROPOX 2015
Ropox Verti-Inside Cabinet height of 70.4 cm Cabinet height above 70.4 cm Cabinet depth 26.5cm/10,2in or 31cm/12,2in and cabinet width 40-100cm / 15,7 – 39,3 in (30-40404 to 30-40420) Construction – see dimensions on the following page Minimum area for reinforcement of wall. Wall material must be suitable for screw mounting. Area for electric installation. Area for conduit. Cabinet height of 70.4cm/27,6in or more. For cabinet heights above 70.
Ropox Brackets For wall cabinets (30-80000) Construction – see dimensions on the following page Minimum area for reinforcement of wall. Wall material must be suitable for screw mounting. Max. load 90kg evenly distributed over the cabinet up to 80cm/31,5in in width, according to DS/EN 12182, based on 12 screws/bolts.
Ropox Brackets For worktops (30-80006) Construction – see dimensions on the following page Minimum area for reinforcement of wall. Wall material must be suitable for screw mounting. Area for electric and plumbing installations. Max. load 75kg/165lb evenly distributed up to 80cm/31,5in in width, according to DS/EN 12182.
Ropox FlexiBasic 600 - 2000 mm / 23,6 – 78,7 in (30-63060 - 30-63200) Construction – see dimensions on the following page. Minimum area for reinforcement of wall. Wall material must be suitable for screw mounting. Area for electric and plumbing installations. Max. load 150kg/331lb evenly distributed over the worktop up to 300cm/118in in width, according to DS/EN 12182.
Ropox FlexiBasic 2050 – 3000 mm / 80,7 – 118 in (30-63205 - 30-63300) Construction – see dimensions on the following page Minimum load capacity per screw/bolt: 40 kg/ 88lb The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type. Minimum area for reinforcement of wall. Wall material must be suitable for screw mounting. Area for electric and plumbing installations. Max.
Ropox FlexiManual 600 - 2000 mm / 23,6 – 78,7 in (30-65060 - 30-65200) Construction – see dimensions on the following page Minimum area for reinforcement of wall. Wall material must be suitable for screw mounting. Area for electric and plumbing installations. Max. load 150kg/330lb evenly distributed over the worktop up to 300cm/118in in width, according to DS/EN 12182.
Ropox FlexiManual 2050 – 3000 mm / 80,7 – 118 in (30-65205 - 30-65300) Construction – see dimensions on the following page Minimum load capacity per screw/bolt: 40 kg/ 88lb The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type. Minimum area for reinforcement of wall. Wall material must be suitable for screw mounting. Area for electric and plumbing installations. Max.
Ropox FlexiElectric 600 – 3000 mm / 23,6 – 118 in (30-66060 - 30-66200) Construction – see dimensions on the following page Minimum area for reinforcement of wall. Wall material must be suitable for screw mounting. Area for electric and plumbing installations. Max. load 150kg/330lb evenly distributed over the worktop up to 300cm/118in in width, according to DS/EN 12182.
Ropox FlexiElectric 2050 – 3000 mm / 80,7 – 118 in (30-66205 - 30-66300) Construction – see dimensions on the following page Minimum area for reinforcement of wall. Wall material must be suitable for screw mounting. Max. load 150kg/330lb evenly distributed over the worktop up to 300cm/118in width, according to DS/EN 12182.
Ropox FlexiCorner Construction – see dimensions on the following page Max. load 150kg/330lb evenly distributed over the worktop up to 300cm/118in width, according to DS/EN 12182. Minimum area for reinforcement of wall. Wall must be suitable for screw mounting. Min. load capacity per screw/bolt: 40 kg/ 88lb Area for electric and plumbing installations. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.
Ropox FlexiPlus - 2 Legs 600 – 2400 mm / 23,6 – 94,5 in (30-90060 - 30-90244) Construction – see dimensions on the following page Minimum area for reinforcement of wall. Wall material must be suitable for screw mounting. Max. load 150kg/330lb evenly distributed over the worktop up to 300cm/118in in width, according to DS/EN 12182.
Ropox FlexiPlus - 3 Legs 2450 – 3000 mm / 96,5 – 118 in (30-90245 - 30-90300) Construction – see dimensions on the following page Minimum area for reinforcement of wall. Wall material must be suitable for screw mounting. Max. load 150kg/330lb evenly distributed over the worktop up to 300cm/118in width, according to DS/EN 12182.
Ropox FlexiPlusCorner (30-91XXX-XXX) Construction – see dimensions on the following page Minimum area for reinforcement of wall. Wall must be suitable for screw mounting. Area for electrical and plumbing installations. Max. load 150kg/330lb evenly distributed over the worktop up to 300cm/118 in width, according to DS/EN 12182. Min.