Specifications
18
OLD DESIGN 12 & 14 cu. ft. Top-Mount
AIR CIRCULATION
The evaporator fan circulates air inside the refrig-
erator and freezer sections. (
Fig. 24)
Most of the
air circulates inside the freezer compartment, and
returns to the evaporator from slots in the front and
rear of the freezer floor. The return air travels be-
tween the floor and the liner, where it joins other
return air at the back, flowing beneath the evapora-
tor cover and up through the evaporator coil.
Cold air is also sent to the refrigerator section
through the air duct at the rear of the freezer sec-
tion. The cold air enters the refrigerator section
through a diffuser. Part of the air is forced forward
where is passes through the front part of the com-
partment and the shelves in the door. Part of the
cold air is directed down the back of the compart-
ment to cool the lower portion of the refrigerator
section. The warmed air is then returned to the
freezer section through two air return ducts.
Figure 24 Key:
1 - Evaporator 7 - Separator
2 - Evaporator Cover 8 - Air Duct
3 - Evaporator Fan 9 - Diffuser
4 - Fan Scroll 10 - Cold Air Discharge
5 - Cold Air Discharge 11 - Cold Air Discharge
6 - Return Air Louvers 12 - Air Return (2)
Fig. 24
7
12
10
11
9
8
6