Install Manual

Periodical Inspection
Tools Required for Assembly
2
Roof Tech recommends a thermal splice every 14 Ft., however, it must be determined
by the installer based on the rail system installation instructions. The installer
must also determine the maximum allowed span and cantilever design parameters
recommended by the rail system manufacturer. The RT-MINI can be installed on
low slope roofs (Metal, EPDM, TPO, SBS Modified Bitumen/Torch-on, Asphalt) and
steep slope roofs (Asphalt shingles, Metal). For low slope roofs, make sure there is
positive drainage.
Periodical Inspection
Roof Tech Inc. recommends inspecting installed racking system periodically for loose
components, loose fasteners and any corrosion. If found, those components are to be
re-tightened, or replaced immediately. When a PV module needs to be removed from
the PV array for maintenance and/or replacement, the electric bonding system may
need to be temporarily restored to maintain the electrical bonding path. Please make
sure the system electrical circuits and disconnects are in the open position and the
entire system is powered down. Cover the fronts of modules in the array with an
opaque material to stop the production of electricity. Use appropriate safety
equipment such as insulated tools and insulating gloves to protect yourself.
Maintenance of the PV modules should be carried out by licensed contractors,
according to the PV manufacturers installation/maintenance instructions and Roof
Tech’s installation instructions.
Maintenance should not be conducted under a wet and/or high wind conditions.
Tools Required for Assembly
Tools needed for installing the RT-MINI
Hex bit socket (8 mm)
Drill andφ3 mm Drill Bit for sheet metal (for Installation on Metal Roof)
Measuring tape
Chalk line
L-Foot mounting option
Item
W5/16 or M8 Bolt