Owner's manual
Chassis:
•
Up to 100 I/O Modules*
•
Power Supply Filter Module
•
AUX Relay Modules
•
Communications Module
System Size:
•
Basic Cabinet Module is 3.50 in.
(88.90mm) x 3.50 in. (88.90mm)
Enclosures:
•
Weather Proof
- NEMA 4 (optional)
- NEMA 4X (optional)
- NEMA 12 (optional)
•
Panel Mount
•
Surface-Mount
•
19” Rack-Mount
*Multiple chassis can be connected to share communications
capabilities up to a maximum of 100 Modules.
FEATURES
Alarm Display LEDs:
•
Minimum of 4 LEDs per window
•
Colors: Red, Green, Yellow, White
and Blue
Dual Redundancy:
(-1000 & -2000 Models Only)
Built-In Diagnostics:
•
Hardware startup
•
Periodic Maintenance
PUSHBUTTON INPUTS
•
Front Bezel Pushbuttons
•
Rear Input Terminals
•
via Network Interface
- Silence
- Acknowldge
- Reset
- First-Out Reset
- LED Test
Lamps, Logic:
•
24Vdc
Field Contacts:
•
Vdc: 24, 48, or 125 Vdc
•
Vac: 115, 240 Vac
X11-2048 INTERFACE MODULE
Communications with the SER/HMI or
a Host via a 10/100 BaseT Interface via:
•
Ronan Proprietary Protocol
•
ModBus RTU Protocol
•
DNP 3.0 Protocol via Ronan REC-UCM
(Optional)
•
Alarm module monitoring generates
system error with missing module.
•
Continuous alarm module conguration
monitoring. (Veries each alarm module
for correct conguration and recongures
improperly congured modules)
Facilitates and preserves
Alarm Module conguration
X11-2047 ALARM MODULE
(4) Opto-Isolated Channels
per module featuring:
•
Output Response 1 to 16383mS
•
H/W First-Out Discrimination 1mS
•
S/W First-Out Discrimination <100mS
ENVIRONMENT
•
Operating Temperature
- 0 to 60º C (32 to 140ºF)**
•
Storage Temperature
- 40 to +85ºC (-40 to +185ºF)
•
Humidity 0-95% RH, non condensing
** Operating at temperatures over 50ºC for more than a few
hours at a time will shorten the life of the system. The average
temperature over life of the system should be <50ºC, but
never exceeding 60ºC
WARRANTY
Ronan warrants equipment of its own manufacture to be free
from defects in workmanship and material under normal
conditions of use and service, and will replace any component
found to be defective, on its return, transportation charges
prepaid, within one (1) year of its original purchase. This warranty
carries no liability, either expressed or implied, beyond our
obligations to replace the unit which carries the warranty.
Extended Warranties are available.
28209 Avenue Stanford, Valencia, CA 91355 U.S.A. • 800-327-6626 • Fax 661-295-6063
http://www.ronan.com E-Mail: sales@ronan.com
DISPLAY PRODUCTS DIVISION
TECHNICAL SPECIFICATIONS
SYSTEM CONFIGURATIONS
Fully Congurable Using the
Ronan Conguration Tool
(software provided):
Event Time Stamping to 1mS
resolution with Date and Time of Day
correlation when an external IRIG-B
Timing Source is provided
Stores latest 1000 events in
distributed, non-volatile memory
Compatible with the Ronan’s
X1001
SER/HMI, X110 and
X118
Remote Alarm Annunciators
SYSTEM VOLTAGE
•
1500V Isolation to Ground and
Channel-to-Channel
•
Vdc: 24V, 48V or 125V Vac: 115V or 240V
(Selectable by Module)
•
Wetted or Dry Contacts
(Selectable by Module)
•
Normally Open/Normaly Closed
Contact Sensing
(Field Selectable Congurable by Channel)
•
Input Response Time < 1mS
•
Multiple Filter Options
(S/W Congurable by Channel)
•
Hot swapable (remove and replace
module without disrupting system
operation)
•
Field contact Debounce lter with:
- Filters for each eld contacts normal and
alarm transition
- Integrating and non integrating lter types
- Units in miliseconds, seconds, and minutes
•
Via TCP/IP over a network (LAN)