Chassis:
Up to 100 I/O Modules*
Power Supply Filter Module
AUX Relay Modules
Communications Module
System Size:
Basic Cabinet Module is 3.50 in.
(88.90mm) x 3.50 in. (88.90mm)
Enclosures:
Weather Proof
- NEMA 4 (optional)
- NEMA 4X (optional)
- NEMA 12 (optional)
Panel Mount
Surface-Mount
19” Rack-Mount
*Multiple chassis can be connected to share communications
capabilities up to a maximum of 100 Modules.
FEATURES
Alarm Display LEDs:
Minimum of 4 LEDs per window
Colors: Red, Green, Yellow, White
and Blue
Dual Redundancy:
(-1000 & -2000 Models Only)
Built-In Diagnostics:
Hardware startup
Periodic Maintenance
PUSHBUTTON INPUTS
Front Bezel Pushbuttons
Rear Input Terminals
via Network Interface
- Silence
- Acknowldge
- Reset
- First-Out Reset
- LED Test
Lamps, Logic:
24Vdc
Field Contacts:
Vdc: 24, 48, or 125 Vdc
Vac: 115, 240 Vac
X11-2048 INTERFACE MODULE
Communications with the SER/HMI or
a Host via a 10/100 BaseT Interface via:
Ronan Proprietary Protocol
ModBus RTU Protocol
DNP 3.0 Protocol via Ronan REC-UCM
(Optional)
Alarm module monitoring generates
system error with missing module.
Continuous alarm module conguration
monitoring. (Veries each alarm module
for correct conguration and recongures
improperly congured modules)
Facilitates and preserves
Alarm Module conguration
X11-2047 ALARM MODULE
(4) Opto-Isolated Channels
per module featuring:
Output Response 1 to 16383mS
H/W First-Out Discrimination 1mS
S/W First-Out Discrimination <100mS
ENVIRONMENT
Operating Temperature
- 0 to 60º C (32 to 140ºF)**
Storage Temperature
- 40 to +85ºC (-40 to +185ºF)
Humidity 0-95% RH, non condensing
** Operating at temperatures over 50ºC for more than a few
hours at a time will shorten the life of the system. The average
temperature over life of the system should be <50ºC, but
never exceeding 60ºC
WARRANTY
Ronan warrants equipment of its own manufacture to be free
from defects in workmanship and material under normal
conditions of use and service, and will replace any component
found to be defective, on its return, transportation charges
prepaid, within one (1) year of its original purchase. This warranty
carries no liability, either expressed or implied, beyond our
obligations to replace the unit which carries the warranty.
Extended Warranties are available.
28209 Avenue Stanford, Valencia, CA 91355 U.S.A. • 800-327-6626 • Fax 661-295-6063
http://www.ronan.com E-Mail: sales@ronan.com
DISPLAY PRODUCTS DIVISION
TECHNICAL SPECIFICATIONS
SYSTEM CONFIGURATIONS
Fully Congurable Using the
Ronan Conguration Tool
(software provided):
Event Time Stamping to 1mS
resolution with Date and Time of Day
correlation when an external IRIG-B
Timing Source is provided
Stores latest 1000 events in
distributed, non-volatile memory
Compatible with the Ronans
X1001
SER/HMI, X110 and
X118
Remote Alarm Annunciators
SYSTEM VOLTAGE
1500V Isolation to Ground and
Channel-to-Channel
Vdc: 24V, 48V or 125V Vac: 115V or 240V
(Selectable by Module)
Wetted or Dry Contacts
(Selectable by Module)
Normally Open/Normaly Closed
Contact Sensing
(Field Selectable Congurable by Channel)
Input Response Time < 1mS
Multiple Filter Options
(S/W Congurable by Channel)
Hot swapable (remove and replace
module without disrupting system
operation)
Field contact Debounce lter with:
- Filters for each eld contacts normal and
alarm transition
- Integrating and non integrating lter types
- Units in miliseconds, seconds, and minutes
Via TCP/IP over a network (LAN)