Specifications

Page 36 RollSeal SC-325 & SC-650 Controllers Part No 4801-5156 Rev 10-2014
12.5 Connecting AC Power to the Smart Controller
Inset A
Inset A
J Box
Inset B
OR
Inset C
OR
Smart Controller Right & Left Side Compartments
Inset B
Inset C
SWX2: AC Voltage
Selection Switch
J1: AC Voltage
Selection Jumper
WARNING!
Dangerous High Voltages!
Allow Approximately 5 Minutes For The Controller To
Power-Down Before Changing Switch Settings, Jumper
Placement, Or Wiring.
WARNING!
Only a qualified electrician should
install and/or service this equipment.
Failure to observe precautions could
result in equipment damage, severe
bodily injury, or loss of life.
The SC-325 Controllers are factory preset to 115 VAC and
the RS-500 Doors factory prewired to require a 115 VAC
power supply.
The SC-650 Controllers are factory preset to 230 VAC and
the RS-600 Doors factory prewired to require a 230 VAC
power supply.
The SC-325/SC-650 Controllers and RS-500/600 Doors can
be field upgraded to accommodate either 115 VAC or 230
VAC power supply. If the desired power supply voltage is
different from the factory preset/prewired voltage, the
appropriate version Brake Rectifer must be ordered
separately, field-installed on the RS Door, and the SC
Controller switch & jumper settings changed accordingly.
!
!