Specifications
Part No 4801-5156 Rev 10-2014 RollSeal SC-325 & SC-650 Controllers Page 19
6.3 Switch Settings
SWX1 contains two separate switches. The first switch (SWX1:1) controls the Safety Action and the second
switch (SWX1:2) determines the Encoder Selection as follows:
PCB 154 SWX1:1 – SAFETY ACTION
Selects the operation of the door when the Safety Beam is interrupted during closing. If
at any time while the door is closing, the Safety Beam is interrupted, the door will stop.
Then if SWX1:1 is “On” the door will proceed to open to its full open position. If
SWX1:1 is “Off” the door will stop and await a command to either continue opening or
to close. See Section 12.1 for the location of SWX1 on the printed circuit board.
PCB 154 SWX1:2 – ENCODER SELECTION
Selects between the use of one encoder (SWX1:2=Off) or two encoders (SWX1:2=On)
when determining the door position. Some doors will be equipped with two encoders.
See Section 12.1 for the location of SWX1:2 on the printed circuit board.
PCB 154 SWX2 Switch and MOTOR DRIVE J1 Jumper– VOLTAGE SELECTION
The Smart Controller contains one switch and one jumper which must be set prior to
initial use and application of power. Ensure that SWX2 and J1 are both set according to
the specific required voltage. Refer to Section 12.1 (for V1) or 12.3 (for V2) and 12.5
for the location of SWX2 on PCB 154 and J1 on the Motor Drive board assembly.
The SC-325 controllers are factory preset to 115 VAC and the RS-500 doors factory
prewired to require a 115 VAC power supply. The SC-650 controllers are factory preset
to 230 VAC and the RS-600 doors factory prewired to require a 230 VAC power supply.
The SC-325 controller can be field upgraded to accommodate either 115 VAC or 230
VAC power supply. If the desired power supply voltage is different from the factory
preset/prewired voltage, the appropriate version Brake Rectifier must be ordered
separately, field-installed on the RS Door, and the SC controller switch & jumper settings
changed accordingly. Refer to Section 12.6 for specific RS-500/600 Motor Brake
Rectifier wiring diagrams.
Warning!
DO NOT Turn The Power ON Until All Of The Following Items Are Completed:
All Wire And Cable Connections Are Completed.
The Voltage Selection Switch And Jumper Are Set To Match The Required
Supply Voltage.
The Motor Brake Rectifier Is Wired Accordingly To Match The Required Supply
Voltage.
6.4 Door Setup
The door limits are used to adjust the door position in the full open and closed positions. To set the door
limits, use the following steps:
(1) Depress the Mode button (●) for at least 5 seconds. P1 (Close Time Delay) will be then
be displayed in the Display Indicator.
(2) Depress and release the Mode button until PS1 (Change Program Limits) is displayed.
(3) Depress Up ( ) until “yes” is displayed.
(4) Depress the Mode button again (●). PS2 (Set Open Limit) will be displayed.
(5) The door will proceed to the open limit and then stop. Once the door stops, adjust open
limit using the Up ( ) or Down ( ) buttons until open limit is satisfactory.
(6) Depress the Mode button (●) again. PS3 (Set Closed Limit) will be displayed.
(7) The door will proceed to the closed limit and then stop. Once door stops, adjust this limit
using the Up ( ) or Down ( ) buttons until the close limit is satisfactory.
(8) Depress the Mode button (●) again and the controller will exit the programming mode
and return to displaying the actual position.
(9) The setup is now complete.
!