4801-5159 Rev 01-2015 Technical Installation and Service Manual Page 9
3. Center door assembly on clear opening. Align the bottom of
each vertical member with the respective framing board or
posts of the clear opening.
Note: The vertical members should be aligned so that
their outer flanges will exactly overlap with the
framing boards or posts when the door
assembly is raised into position.
4. Assemble workers and each side
of the door assembly. See
Diagram 4G.
IMPORTANT: SLOWLY LIFT TOP
OF DOOR
ASSEMBLY TO
RAISE
THE DOOR.
5. Lean door assembly upright against clear opening.
6. Carefully press flanges of the door assembly flush against faces of framing boards or posts.
7. Fasten Tek screws (in steel) or lag screws (in wood) through the flanges on sides of door assembly.
Securely tighten all screws.
8. On the lower and upper flanges of the horizontal member there are attachment points for fastening
screws. Fasten Tek screws (in steel) or lag screws (in wood) through the holes. This secures the top of
the door to the clear opening.
9. Locate the two floor mounting holes at the bottom of the left & right tracks. See Diagram 4H.
10. Drill a 1/4" hole and install Hammer Set Anchors (1002-6030) in both right and left tracks. See
Diagram 4H.