Service manual
Page 8 Technical Installation and Service Manual 4801-5159 Rev 01-2015
4.6 Infrared Sensor Connectors
Located at the bottom of each vertical member is an infrared
detector. The detector on each vertical member operates as a
safety device if the infrared beam is interrupted. Door can be
set to stop if beams are broken while closing, or to stop and
reverse to the full open position. Refer to the RollSeal SC-325
Controller Manual for more information.
1. Locate female connector on vertical member. This
connector is attached to the infrared detector.
2. Locate male connector on horizontal member. Unroll
cable until connectors meet. Pull enough slack for
photo-eye replacement and troubleshooting
purposes.
3. Plug connectors together. Make sure connectors
interlock.
4. Repeat for both infrared detectors.
5. Cable ties and adhesive mounts are supplied to secure
wire to the inside of tracks.
4.7 Fastening Door Assembly to Clear Opening
1. Use a tape measure and make sure that the
overall height and overall width of the clear
opening meet the requirements: Overall Height =
Height + 20.688 in. (52.55 cm), Overall Width =
Width + 16.4 in. (41.66 cm). Reference Table 1,
Page 3 and Diagram 4A, Page 5.
2. Make sure that door assembly is plumb and
square. See Diagram 4F.
NOTE: For each vertical member, unroll respective sensor cable attached to horizontal member until
cable reaches the connector attached to the vertical member. Plug connectors together. Some
slack must be left at photo eyes for replacement purposes.