4.4 Attachment Points of Door
When sizing the clear opening for attachment of the door, pay close attention to the following guidelines.
Door flanges have pre-drilled holes that serve as mounting points of door.
Flange widths are shown in Diagram 4B.
1. Make sure that door assembly is plumb and square.
2. The top unit has a top flange and a bottom flange. Make sure these flanges overlap framing.
3. The vertical members have inner flanges and outer flanges. The outer flanges have pre-drilled holes that
serve as attachment points. Make sure the outer flanges overlap framing.
4. When door is raised in front of clear opening (Section 4.7, Page 8), flanges must be flush against framing
for attachment of screws.
Framing Members
Bottom View