Service manual

4801-5159 Rev 01-2015 Technical Installation and Service Manual Page 23
14.2 Close Direction Test
Momentarily place the jumper on the pins of Out to Close. The door
should close to its full close position. Care should be taken that this wire
only touches these two points.
14.3 Stop Position Test
1. Momentarily place the jumper on the Open or Close direction.
The door will start to move in that direction.
2. Before the door gets to its full limit, momentarily place the jumper
across the Out to Stop position. The door should stop at this
point. Care should be taken that this wire only touches the
specified points.
14.4 Sequential SWX Test and Manual Position Test
Momentarily place the jumper on the pins of Out to Manual. The door
should open or close to its full limit position. The direction will depend on
the last signal or input it received from this location.
Each time you make contact on this point the door will move opposite of
the previous move. Care should be taken that this wire only touches these
two points.
14.5 Timed Direction Test
The door must be closed before performing this test.
Momentarily place the jumper on the pins of Out to Timed. After the
door is opened and all safety sensors are clear, a timer will count down
and close the door automatically. In order for the timed feature to work,
the door must have initially been in a closed or stopped position. If the
door is open (by an open test or some other means), the timer will not
operate and the door will remain open. Care should be taken that this
wire only touches these two points.