Service manual

Page 20 Technical Installation and Service Manual 4801-5159 Rev 01-2015
Feedback Errors (Cont.)
Code
Condition
Panel
Movement Problem Area Possible Solutions
ECF2 Opening,
Direction
Fault
Down Egress Strap Check Egress Strap to ensure that the strap is
in the correct reset Limit Mark position and not
pulled out of position.
12 Jog Mode
The Jog Mode will permit an operator to manually control the
position of the door with the Up () and Down () arrow
buttons. To enter the Jog Mode, press both the Up () and
Down () arrows at the same time for at least 5 seconds. The
controller will indicate the Jog Mode in the display as shown
below.
In the Jog Mode the door can be opened and closed and is not
affected by the Home Limit Switch or the Safety Beam. The
operator must carefully watch the door movement when nearing the full open and full closed positions. To exit the
Jog Mode, press and hold the Up () and Down () arrow buttons for at least 5 seconds. The Controller will
return to the normal operating mode with the Actual Position shown in the display.
When returning to the normal operating mode, the controller will not know the exact position that the operator has
left the door when exiting the Jog Mode. Therefore, the Controller will display a series of three horizontal bars.
Upon the next command the door will slowly proceed to the full open position to reset its memory. The door will
always follow this procedure after exiting the Jog Mode.
Actual Position
Open Speed
Close Speed
TotalCycles
Service Cycles
Door Obstruction
(Cycles 100)
Mode
JOG
JOG Mode