7 Installation
7.1 Tools Required
3/8 in. (10 mm) Power screwdriver (portable)
3/16 in. (5 mm) Drill bit and power drill
3/8 x 1 in. Bolts and nuts (supplied)
Socket
Hammer
Tape measure
Carpenter's level
NOTE: Other Tools May Be Required According To Installation.
7.2 Overview
The RS-500/600 Door is shipped with pre-assembled vertical members (left track and right track), and a pre-
assembled horizontal member (head unit). When components are received, check for damaged, loose or
missing parts. If there are damaged or missing parts contact your RollSeal distributor immediately. Please
read and understand all instructions in this manual before beginning installation.
7.3 Adjusting the Clear Opening
Locate your particular system in Table 1 or Table 2, Pages 9-10. Read the value of height and width of the
clear opening for the door size that you are installing. This gives the required dimensions of the clear
opening. If necessary, adjust the dimensions of the mounting posts or framing members to the height and
width of your RS-500/600 Door System as shown in Diagram 7A. Refer to Section 7.4 (Page 13, Diagram
7B) for details of attaching door to framing members. Framing material must provide suitable support for
attachment of screws.
Make sure that mounting posts or framing members are positioned so that the screw holes of the outer flanges
of the vertical members will align with the mounting posts or framing (Section 7.4, Page 13, Diagram 7B).
Make sure that there is room for the motor and control box without encountering any obstructions.
NOTE: Allow 1' (30.4 cm) minimum, preferably 18" (45.7 cm) clearance above the Head Unit for
future panel maintenance or replacement.