Installation manual

Part No 4801-5154 Rev 01-2015 RS-500/600 Series Doors Page 47
30.3 Resetting (Closing) The Door
After the RollSeal RS-500 Door is opened by using the Emergency Egress Strap, the door must be carefully
re-set to ensure proper operation in the future.
1. Firmly hold strap. See Diagram 30D.
2. Press the Cam Buckle Release. See Diagram 30E.
3. Gradually feed strap through Cam Buckle until door is closed at bottom.
4. Return Emergency Egress Tool to retainers for future use.
5. Cycle the door up and down in normal operating mode to ensure proper re-setting of the door.
Adjust if necessary. Door should now function normally.
Diagram 30D
Diagram 30E
CAUTION!
When the Cam Buckle is released, the door will rapidly close unless tension is held on the strap.
Keep fingers away from buckle while closing.
!
Firmly
hold
strap.
Press the Cam
Buckle Release