Installation manual

Part No 4801-5154 Rev 01-2015 RS-500/600 Series Doors Page 39
25 Manual Operation RS-500/600 Series Door (Brother Motor
Only)
25.1 Operating Instructions
The RS-500/600 Series Door can be operated manually in the event of a power outage or if there is a motor
malfunction. To operate the door manually, perform the following instructions.
Warning!
Disconnect All Electrical Power To Motor Before Attempting
To Operate The Door Manually!
Warning!
The Curtain Is Released When Brake Lever Is Disengaged.
Do Not Disengage Brake Until Door Opening Is Clear!
If door is OPEN (door curtain raised) perform the following steps:
1. Locate brake lever at bottom of motor. (See diagram below).
2. Carefully release brake by flipping lever down.
CAUTION: Curtain will drop when brake is released.
If door is CLOSED (door curtain lowered) perform the following steps:
1. Turn power off to the controller
2. Locate brake lever at bottom of motor.
3. Carefully release brake by flipping lever down.
4. Motor shaft is accessible from bottom of
motor. Use provided Crank Handle to
rotate motor shaft.
5. Carefully turn motor shaft
counterclockwise to raise door
curtain.
Note: The drive (as viewed
from the 'motor end' of door) is
counterclockwise rotation of the motor
shaft.
5. When door curtain has
been raised
to desired height, flip
brake lever
up to engage brake.
6. If you do not release the
brake it could result in
damage to the motor.
!
!