Installation manual
Part No 4801-5154 Rev 01-2015 RS-500/600 Series Doors Page 37
PROGRAM PARAMETERS
P1 - Close Time Delay (Seconds)
P2 - Acceleration Range
P3 - Deceleration Range
P4 - Door Interlock
0 - OFF
1 - Sequential Interlock
2 - Passive Interlock
3 - Freezer Mode - No Interlock
P5 – Auxiliary On Time
P6 – Auxiliary Off Time
P10 - Service Cycle Reset
0 - No
1 - Yes
P11 - Service Reminder (Cycles x 100)
P12 - Input Status
PS1 - Set Limits?
PS2 - Set Open Limit
PS3 - Set Close Limit
*Refer to the 4801-5156 SC-325 and SC-650 product manual for additional smart controller information.
23.2 Open and Close Door
1. Depress manual control button. Door curtain will unroll to 'closed' position.
2. Depress manual control button. Door curtain will roll up to 'open' position.
Depress button to open or close door as desired.
Open and close the door a few times to test door operation and remove any wrinkles in the door curtain. The
door is now ready for operation.