Specifications

17
RC-20XL
11.AUX IN (NORMAL) check
Set the PHRASE SELECT volume to the ‘6’ position.
Verify that “LOOP QUANTIZE” is dark and “LOOP PHRASE” is lit.
Verify that the output waveform is the same as the waveform shown in
the diagram.
fig.NORMAL_40
(0.5V/DIV, 1mS/DIV)
0.6Vp-p 0.1Vp-p
12.AUX IN (FLAT AMP SIMULATE) check
Set the PHRASE SELECT volume to the ‘7’ position.
Verify that “LOOP PHRASE” is dark and “INST & MIC” is lit.
Verify that the output waveform is the same as the waveform shown in
the diagram.
fig.F-AMP_40
(0.5V/DIV, 1mS/DIV)
2.0Vp-p 0.2Vp-p
Press the FS-5U that is connected to the REVERSE jack, and verify that
the waveform does not decrease.
13.AUX IN (CENTER CANCEL) check
Set the PHRASE SELECT volume to the ‘8’ position.
Verify that “INST & MIC” is dark and “NORMAL” is lit.
Verify that there is no longer an output waveform.
14.AUX IN (L ch) check
Set the PHRASE SELECT volume to the ‘9’ position.
Verify that “NORMAL” is dark and “CENTER CANCEL” is lit.
Input only the L channel to AUX IN.
Verify that the output waveform is the same as the waveform shown in
the diagram.
fig.L-ch_40
(0.5V/DIV, 1mS/DIV)
1.8Vp-p 0.2Vp-p
15.solder spot check
Set the PHRASE SELECT volume to the ‘10’ position.
Verify that “CENTER CANCEL” is dark and “FLAT AMP SIMULATE”
is lit.
Verify that there is no longer an output waveform.
Set the PHRASE SELECT volume to the ‘11’ position.
Verify that all LEDs are lit except for “PEAK.”
Verify that the output waveform is the same waveform as shown in the
diagram.
fig.DA_40
(0.5V/DIV, 1mS/DIV)
200Hz, 2.2Vp-p 0.2Vp-p
16. PHRASE SELECT volume check
Set the PHRASE SELECT control to the “10” position.
Confirm that the FLAT AMP SIMULATE LED goes off.
Set the PHRASE SELECT control to the “9” position.
Confirm that the CENTER CANCEL LED goes off.
Set the PHRASE SELECT control to the “8” position.
Confirm that the NORMAL LED goes off.
Set the PHRASE SELECT control to the “7” position.
Confirm that the INST & MIC LED goes off.
Set the PHRASE SELECT control to the “6” position.
Confirm that the LOOP PHRASE LED goes off.
Set the PHRASE SELECT control to the “5” position.
Confirm that the LOOP QUANTIZE LED goes off.
Set the PHRASE SELECT control to the “4” position.
Confirm that the TAP TEMPO LED changes from red to orange.
Set the PHRASE SELECT control to the “3” position.
Confirm that the TAP TEMPO LED goes off.
Set the PHRASE SELECT control to the “2” position.
Confirm that the REVERSE LED goes off.
Set the PHRASE SELECT control to the “1” position.
Confirm that all LEDs other than the PEAK LED are lit.
Confirm that the “POWER” indicator is lit.
17.Noise check
Set the PHRASE SELECT volume to the ‘2’ position.
Connect a 47k ohm short plug to the INST jack, a 150k ohm short plug
to the MIC jack, and a 1 k ohm stereo short plug to the AUX IN jack.
Connect a monitor amp to OUTPUT.
Set the INST volume and MIC volume to the maximum.
Drop the unit from a height of 10 cm, and verify that no abnormal noise
is output.
Turn the INST volume and MIC volume, and verify that no abnormal
noise is output.
With the INST volume and MIC volume at the maximum positions,
measure the residual noise, and verify that it is less than -78 dBm (IHFA).
18.Battery operation check
Put the battery in the battery compartment and insert the plug into the
OUTPUT jack.
Verify that POWER is lit