User Manual
85
An Error Message Appears
7. Troubleshooting
Error num-
ber
Error message
(built-in panel)
Cause
Action/procedure
103B-0000
The automatic cor-
rection is not yet n-
ished.
Cutting may have been
started without rst per-
forming automatic cor-
rection.
1
Select "OK" on the built-in panel, and then
press [ENTER]. This will clear the error.
2
Perform automatic correction until com-
pletion.
P. 35 "Correcting the Cutting Machine (Auto-
matic Correction)"
The rmware version may
not correspond to the
VPanel version.
1
Update both the rmware and VPanel to their
latest versions.
"Setup Guide"
2
Perform automatic correction until com-
pletion.
P. 35 "Correcting the Cutting Machine (Auto-
matic Correction)"
-
You cannot set the
origin with the ma-
chine coordinate
system.
-
Procedure (RML Mode)
1
Press [COORD. SYSTEM] to switch to the user
coordinate system.
2
Set the origin again.
Procedure (NC Mode)
Press [COORD. SYSTEM] to switch to the
coordinate system for which you want to set
the origin.
1044-0000
The automatic set-
ting of Z0 failed.
The following are likely
reasons.
• The Z0 sensor has not
been connected.
• The Z0 sensor surface is
dirty.
• The detection pin surface
is dirty.
1
Select "OK" on the built-in panel, and then
press [ENTER]. This will clear the error.
2
Connect the Z0 sensor cable again.
3
Position the detection pin directly over the
Z0 sensor.
4
Use the [Z0 SENSE] button to automatically
set the Z user origin again.
1045-****
The error occurred
during synchronizing
the control board.
An error occurred during
control board synchroni-
zation.
Restart the machine.
If the error occurs again after perform the above operations
Contact your authorized Roland DG Corp. dealer.
1046-****
The combination
of rmware version
of the main board
and the sub board
is invalid.
The combination of main
board and sub board rm-
ware versions is invalid.