User Manual

81
An Error Message Appears
7. Troubleshooting
Error num-
ber
Error message
(built-in panel)
Cause
Action/procedure
1018-0000
The chucking sen-
sor was not found.
-
Restart the machine.
If the error occurs again after perform the above operations
Contact your authorized Roland DG Corp. dealer.
1019-0000
The chucking sen-
sor is in an incorrect
status.
-
101A-0000
The chucking motor
experienced exces-
sive current.
-
Restart the machine.
101B-0000
The chucking motor
control circuit expe-
rienced excessive
current.
-
If the error occurs again after perform the above operations
Contact your authorized Roland DG Corp. dealer.
101C-0000
The tool sensor was
not found.
-
101D-****
The #% cutter can-
not be released.
(% is "1" to "6.")
The returning of the tool
bur failed. The inside of the
collet or the ATC magazine
might be dirty.
Procedure
1
Select "OK" on the built-in panel, and then
press [ENTER]. This will clear the error.
2
Remove the tool bur.
P. 45 "Operation of the Tool Bur Replacement
Function (Auto Tool Changer)"
3
Clean the ATC magazine.
P. 31 "Cleaning after Cutting Finishes"
The collet and tool bur
are affixed together and
cannot be separated. The
inside of the collet might
be dirty.
Retighten the collet.
P. 37 "Retightening the Collet"
If the error occurs again after perform the above operations
The collet may be deformed. In this case, replace
the collet, and then perform automatic correction.
101E-****
The #% cutter might
be broken.
(% is "1" to "6.")
The tool bur might be bro-
ken.
1
2
Select "OK" on the built-in panel, and then
press [ENTER]. This will clear the error.
If the tool bur is broken, replace it with a
new one.
The cutting conditions
may be excessively strict.
Review the CAM settings and the shape specied
in the CAD data.
The collet may have come
loose.
Retighten the collet.
P. 37 "Retightening the Collet"
If the error occurs again after perform the above operations
The collet may be deformed. In this case, replace the collet, and then perform
automatic correction.