User Manual
54
"Settings" Dialog Box
Movement des-
tination
View
The spindle
is stopped
before move-
ment.
The spindle head moves to the left edge and the
table moves to the frontmost position. This posi-
tion is called the "view position." Use this position
when loading or removing the cutting tool or the
cutting material.
xxx origin
Moves the tool bur to the origin in the selected
coordinate system.
A origin
Use this when the optional rotary axis unit is at-
tached.
Center of
rotation
Move the tool bur tip to the center of rotation. You
can only select this option when the rotary axis
unit is attached.
Specified
location
Select this to open the "Move to user specied
location" dialog box.
P. 62 ""Move to user specied location" Dialog
Box"
Move
Move the tool bur to the selected movement destination. This button is disabled dur-
ing tool bur movement.
Stop
Stop the tool bur. This button is only enabled during tool bur movement.
Coordinate sys-
tem
Select the coordinate system of the origin to set. The options are the same as the
coordinate system for
.
Origin setting
position/
coordinate axis
Set user origin
here
"X," "Y," "Z,"
"XY," "XYZ,"
"A"*
Set the user origin to the current position. (For
RML-1)
Set EXOFS
here
"X," "Y," "Z,"
"XY," "XYZ,"
"A"*
Set the EXOFS to the current position. (For NC)
Set Gxx origin
here
(xx: 54 to 59)
"X," "Y," "Z,"
"XY," "XYZ,"
"A"*
Set the G54 to G59 origin to the current posi-
tion. (For NC)
Set origin us-
ing Z0 sensor
"Z"
Use the Z0 sensor to set the user Z origin. The
"Sensing Z origin" dialog box appears.
P. 59 ""Sensing Z origin" Dialog Box"
Set origin at
center of rota-
tion
"Y," "Z,"
"YZ"
Set the user origin to the center of rotation.
The origin is returned to the position that was
detected with the [Correction] tab.
This is only enabled when the (optional) rotary
axis unit is attached. Before conguring this set-
ting, you have to perform automatic correction.
Set origin at
the left edge of
workpiece
"X"
Set the user origin to the left edge of the
workpiece.
The origin is returned to the position that was
detected with the [Correction] tab.
This is only enabled when the (optional) rotary
axis unit is attached. Before conguring this set-
ting, you have to perform automatic correction.
Set Set the selected origin.
* You can select "A" when the optional rotary axis unit is attached.
6. VPanel Operation (Practical Use)