User Manual
51
6. VPanel Operation (Practical Use)
"Settings" Dialog Box
Click on the top window to display the "Settings" dialog box. You can use this dialog box to congure the operation
settings of the connected machine. When the machine is oine, you can only select the "Environment", "Maintenance", and
"Notication" tabs.
"Preferences" Tab
You can use this tab to set the language and units that are displayed in VPanel.
Unit
Select the unit to use for coordinate values and lengths. Initial setting: Millimeters
Language
Select the language to display on the screen. After you select the language, restart
VPanel to enable this setting.
P. 8 "Exiting VPanel"
"Machine" Tab
You can use this tab to congure settings related to VPanel auto-startup and NC codes. You cannot select this tab when the
machine is oine.
Command set
Select the command set.
Initial setting: Automatic switching between RML-1 and NC code
RML-1 Select this option when using the software included with this
machine.
NC code Select this option when you want to use NC codes.
For details on NC codes, see P. 88 "NC Code Specications"
and the "NC Code Reference Guide" (electronic-format manual)
included with this machine.
Selected
automatically
(RML-1/ NC
code)
Select this option to enable this machine to receive cutting
programs that use either the RML-1 or NC code command set.
NC code set-
ting
Click this button to display the "NC code setting" dialog box.
Use this dialog box to congure NC code settings. This button is
only enabled when "NC code" or "Automatic switching between
RML-1 and NC code" is selected.
P. 58 ""NC code setting" Dialog Box"