Machine Specications
43
Alarm Lamp Connector
PIN number Signal Overview/function
1
(left)
24V Set the output up to 150 mA.
2
ERROR This signal activates when a fatal error occurs.
3
BUSY This signal activates when the machine is operating.
4
(right)
READY This signal activates when preparations are complete.
Connector layout
2 3
4
Output specications
Use 1 24V as the power supply, and then connect the lamp to 2, 3, and 4.
2
3 4
GND
+24 V
Power supply: +24 V (150 mA)
Output: Open collector
Output capacity: 50 mA max.