User`s manual

5-1 Specications
Machine Specications
LPX-1200
Table size
Diameter 130 mm (10 in.)
Maximum scanning area
Plane scanning: Width 130 mm (5 in.), height 203.2 mm (8 in.)
Rotary scanning: Diameter 130 mm (5 in.), height 203.2 mm (8 in.)
Scanning pitch
Plane scanning: width direction 0.1 to 130 mm, height direction 0.1 to 203.2 mm
Rotary scanning: circumference 0.18 to 3.6 degrees, height direction 0.1 to 203.2 mm
Repeat accuracy
±0.05 mm (This gure reects standard scanning conditions established by Roland
DG.)
Maxi mu m ta ble load
weight
5 kg
Laser
Wavelength: 645 to 660 nm
Maximum output: less than 390 μW
(maximum output of the laser light emitted inside housing is 5 mW)
Sensor
Noncontact laser sensor
Scanning method
Spot-beam triangulation
Operating speed
Table rotation speed: 9 rpm, head rotation speed: 4.48 rpm, maximum head movement
speed: 7.58 mm/sec.
Interface
USB interface (compliant with Universal Serial Bus Specication Revision 1.1)
Power requirements
Dedicated AC adapter: AC 100 to 240 V ±10% 50/60 Hz
Machine: DC 19 V, 2.1 A
Power consumption
Approx. 20 W (including AC adapter)
Dimensions
443 [W] x 396 [D] x 609 [H] mm (17-7/16 [W] x 15- 9/16 [D] x 24 [H] in.)
Weight
35 kg
Packed dimensions
620 [W] x 550 [D] x 810 [H] mm (24-1/2 [W] x 21- 5/8 [D] x 31-7/8 [H] in.)
Packed weight
43 kg
Environment
Temperature: 10 to 40ºC (50 to 104ºF) (25ºC [77ºF] or more recommended)
Humidity: 35 to 80% (no condensation)
Included items
AC adapter, power cord, CD-ROM, clay, user's manual, Roland LPX EZ Studio
System Requirements for the Software
Operating system
Windows XP/2000/Me/98
CPU
Pentium II or higher
Memory
128 MB or more
Free hard-disk space re-
quired for installation
Dr.PICZA3: 20 MB or more
3D Editor: 10 MB or more
System Requirements for USB Connection
Operating system
Windows XP/2000/Me/98 (Windows 95 and Windows NT4.0 are not supported.)
Computer
1) Computers preinstalled with Windows 98/Me/2000/XP at the time of purchase
(This includes such computers later upgraded to Windows Me/2000/XP.)
2) Computers on which USB operation is assured by the manufacturer of computers
Whether a USB connection is possible depends on the specications of the computer. To determine whether the computer
you're using is capable of correct USB operation, check with the manufacturer of the computer.
Use a shielded USB cable having a length of three meters or less. Do not use a USB hub or the like.
56