91
4 User's Reference
Meaning
A motor error occurred.
The air temperature where installed is lower than
the ambient temperature at which the unit can
operate (approx. 5°C (41°F) or more lower).
The [SETUP] key was pressed even though no
material is loaded.
Setup was performed with no material at the
correct location.
[Sheet Type] is set to [OPAQUE], but transparent
material was loaded.
An attempt was made to load material that is too
small.
The reflective tape is dirty.
The [SETUP] key was pressed with the pinch
rollers up.
The pinch rollers were raised during setup.
The printing head was returned to its standby
position to be capped, canceling current printing
job.
Because emergency stop was effected more than
10 min.
Continuous operation caused the pump motor to
become hot, so operation was paused to prevent
damage to the motor.
Action
Recovery from this problem is impossible.
Use the POWER key to switch the power off and
back on again.
After rectifying the cause of the error (a material
jam or the like), switch on the power.
Do not leave the unit with the carriage not in
standby position.
Recovery from this problem is impossible. Use
the [POWER] key to switch the power off. First
raise the temperature of the area where installed,
then switch on the power.
Load material at the correct location and press
the [SETUP] key again (see "2-3 Loading the
Material").
When using transparent material, set [SHEET
TYPE] to [CLEAR] (see "4-6 What to Do If...").
Replace with material of loadable size.
Wipe off the grime on the reflective tape, then
perform setup again.
Move the sheet loading levers toward "LOAD"
and lower the pinch rollers, then press the
[SETUP] key (see "2-3 Loading the Material").
Turn power off by pressing [POWER] key to
reset.
Interrupted printing is not resumed. Repeat
printing from the beginning.
Press any key to cancel the message.
Allow the unit to stand for about 30 minutes,
then resume operation.
Messages
MOTOR ERROR
TURN OFF POWER
TEMPERATURE
IS TOO LOW
SHEET SET ERROR
SET AGAIN
PINCHROLL ERROR
LOWER PINCHROLL
AVOIDING DRY-UP
TURN OFF POWER
CANCELED FOR
PROTECTING MOTOR