Troubleshooting
REAC status indicator is red (Off)
If the REAC status indicator in the REAC Driver Control Panel is Red (Off), recheck all Ethernet and power
connections to the PC and REAC system.
Monitoring device is not listed
If an audio device does not appear in the REAC Driver Control Panel Output Monitor ASIO Device list, ensure
that the monitoring device is connected, powered on and is set to the correct sample rate. If the sample rate
on the monitoring device needs to be changed, follow the steps below:
1. Close SONAR
2. Turn the monitoring device off. You do not need to disconnect it from the PC.
3. Change the sample rate on the monitoring device.
4. Turn the monitoring device on. If you use the VS-700R, configure SYNC Source settings.
5. Start SONAR.
6. Open a project.
You do not need to restart your computer in order for this change to take effect.
REAC inputs are not listed/REAC Driver Control Panel does not open
If you have created a new project in SONAR and do not see any REAC inputs available and/or the REAC
Driver Control Panel will not open, it is possible that there was a change in your hardware set-up since it was
last used. Follow the steps below to reset the monitoring device back to the QUAD-CAPTURE/OCTA-
CAPTURE/FA-66/VS-700R.
1. On the Edit menu, click Preferences to open the Preferences dialog.
2. Click Playback and Recording on the left side of the window.
3. In the Driver Mode box, select ASIO.
4. Click Apply.
5. Click Devices on the left side of the window.
6. Clear all of the Input/Output Drivers check boxes.
7. Select all REAC driver check boxes.
8. Click Apply.