Hardware setup
17
•
•
•
•
•
•
S-4000 System
Figure 6. S-4000 System Diagram
The preceding S-4000 system consists of an S-4000S-3208 (32 inputs and 8 outputs) and an S-4000S-0832
with the optional SO-AES4 module.
To record 32 inputs from the S-4000S-3208 into SONAR, use the REAC MODE switches on the front panel to
configure the S-4000S-3208 as the MASTER and the S-4000S-0832 as the SLAVE.
Digital Audio Clock Synchronization is necessary to avoid monitoring problems, such as noises and gaps.
With the optional SO-AES4, the S-4000S-0832 can output AES/EBU and Word Clock digital signals to
synchronize your approved monitoring device. The following digital connections have been tested and
approved:
FA-66
• AES/EBU-to-optical converter
• AES/EBU to S/PDIF Transformer to optical converter
VS-700R
• AES/EBU (direct connection; no converter is necessary)
• Word Clock Direct (direct connection; no converter is necessary)
To use Digital Audio Clock Synchronization, open VS-700R IO Editor and select the appropriate items in the
SYNC SOURCE and DIGITAL 1 INPUT lists.
QUAD-CAPTURE / OCTA-CAPTURE
• AES/EBU to S/PDIF Transformer
Note: The optional SO-AES4 module is available for purchase from your local REAC dealer.
Stage
FOH
S-4000S-0832
+ SO-AES4
(SLAVE)
S-4000S-3208
(MASTER)
SPLIT/BACKUP
DIGITAL OUT
DIGITAL IN
IEEE1394/USB2.0
Headphones
LAN
port
Network cable
(Cat. 5e)
Digital audio clock
Computer
SONAR
+
REAC driver
+
Audio interface driver
Audio Interface
(96 kHz)
S-4000D