SONAR REAC Recording System User’s Guide
M-200i System
Figure 4. M-200i System Diagram
Connect your computer directly to the REAC port of the M-200i.
You must use REAC CONFIG of the M-200i to set the M-200i as MASTER.
For details on how to make settings for the M-200i, refer to its owner's manual.
Set the sample rate of the FA-66/VS-700R to the same sample rate as the M-200i.
To check the sample rate of the M-200i, proceed as follows.
1. Press the SETUP button of the M-200i.
2. Move the cursor to the SYSTEM icon, and press the ENTER button.
3. Note the SAMPLING FREQ setting shown in the screen of the M-200i.
When connecting the REAC port of the M-200i to your computer, use a Cat. 5e cable that is as short as
possible.
The REAC driver can receive up to 40 channels from the M-200i.
To check the audio sources that correspond to the input channels of the REAC driver, proceed as follows.
1. Press the SETUP button of the M-200i.
2. Move the cursor to the PATCHBAY icon, and press the ENTER button.
3. Move the cursor to OUTPUT PATCHBAY, and press the ENTER button.
4. Using the cursor, scroll the screen so you can see the REAC settings for OUTPUT PATCHBAY.
REAC
M-200i
(MASTER)
IEEE1394/USB2.0
Headphones
Computer
SONAR
+
REAC driver
+
Audio interface driver
Audio Interface
(44.1 kHz or 48 kHz)
DIGITAL INDIGITAL OUT
LAN
port
Network cable
(Cat. 5e)
Digital audio clock