Owner`s manual
77
Chapter 8. System Settings and MIDI Applications
Chapter 8
MIDI reception settings
Indication Parameter Explanation Values
AUTO 
CHANNEL
Determines how MIDI messages will be received from ex-
ternal MIDI devices. 
* At the factory settings this is set to “OFF.” 
* Set this “OFF” if you want note messages of the channel 
specified as the Arpeggio Control Channel or RPS Control 
Channel to control arpeggios or RPS from an external 
device.
OFF: 
The patches of each part can be 
played independently according 
to the channel of the MIDI data 
transmitted from an external 
MIDI device. 
ON: 
The patch of the part selected on 
the D2 can be played, regardless 
of the transmit channel of the ex-
ternal MIDI device.
ARPEGGIO 
CTRL CH 
(arpeggio 
control chan-
nel)
Specifies the channel on which note messages from an exter-
nal MIDI device will control arpeggios when Auto Channel 
is “OFF.” When note messages of the specified channel are 
received from an external MIDI device, an arpeggio can be 
generated according to that note data, and will sound the 
current part. At the factory settings this is set to “16.” 
* This setting is ignored if Auto Channel is “ON.”
OFF, 1–16
RPS CTRL 
CH 
(RPS control 
channel)
Specifies the channel on which note messages from an exter-
nal MIDI device will control RPS when Auto CHANNEL is 
“OFF.” RPS can be played by receiving note messages on the 
specified channel. At the factory settings this is set to “15.” 
* This setting is ignored if Auto Channel is “ON.”
OFF, 1–16
RX SYSEX 
(receive sys-
tem exclu-
sive)
Determines whether the D2 will receive system exclusive 
messages. When this setting is “OFF,” system exclusive 
messages will not be received.
OFF, ON
SOFT THRU If this is “ON,” MIDI messages received at the MIDI IN con-
nector will be re-transmitted without change from the MIDI 
OUT connector.
OFF, ON
DEVICE ID 
(device ID 
number)
This setting is necessary only if data is being transmitted 
separately to two or more D2 units. Otherwise, you should 
not change this setting. At the factory settings, the device ID 
number is set to “17.” 
* If you forget the device ID that was used when bulk data 
was saved on an external device, it will no longer be possible 
to receive the saved bulk data.
17–32
RX BULK 
(bulk receive)
Data that was saved on an external device can be sent back 
to the D2. 
For details refer to p. 81.
OFF: 
Data will not be received. 
PTN: 
Data of the current pattern will 
be received. 
ALL: 