Owner`s manual
MaxMotion for Machines Appendix E-235
position. At this point, you should be able to operate the
System One in the same way you have always been with
Super Pro software.
K. Switch the A/B box to B or MaxMotion position and you will
be able to drive the Dahlgren table from MaxMotion in
Windows with all of its features. MaxMotion bypasses all of
the intelligence of the controller and goes directly to the driver
board of the controller.
L. In future, if the controller fails, you have a choice of not to
repair it and simply order an amplifier box from us for a price
that may be less than repairing the controller.
M. Now is the time to explore the capabilities of MaxMotion
software. Read the manual carefully to take advantage of the
features galore.
CAUTIONS:
A. There are no limit switches exist on Dahlgren System One series of
machines.
B. You should use our 10 key keypad implementation to jog the tool to
the starting point of a job. Next, you should NOT use the SURFACE
command to set the Z axis. Simply use Z down key to actuate your
selected solenoids. You may have selected either left or right or both
solenoids.
E3. Installation instructions for MaxAmp Driver box to Dahlgren
System II
STEP ONE
A. Make sure you have at least two printer ports in your Windows
computer.
B. Make sure that your PC meets the minimum requirements
defined in the System Requirements chapter.
C. Connect the MaxMotion ID key to your existing parallel port
in your computer. If you have a printer connected to the
parallel port, disconnect the printer cable, connect the ID key,
tighten the screws, and reconnect the printer cable to the other
side of the ID key.
D. Make sure and connect the MaxAmp unit per installation
instructions in procedure E1.