Owner`s manual

R
AR-200S RS-232C Reference -
36
3 An editing command was received when the AR-200S was not in Delete mode.
4 This error occurs if a setting/delete/record command is transmitted while the
write protect switch of the card is ON.
5 This error occurs when the total number of phrases specified by the PA, PU, or
CE commands exceeds the maximum value (100), or when the specified
parameter value is outside of the limit of the maximum value.
6 This error occurs when the characters being set for a phrase name or card
name exceed the maximum value.
7 This error occurs when characters other than numerals (0 - 9) are used to
specify an integer.
8 This error occurs when you attempt to specify a previously recorded phrase as
a pattern phrase.
9 This error occurs when you attempt to record or copy a phrase on an already
recorded phrase.
10 There is no remaining card capacity.
20 The command could not be executed for some other reason.
21 Unsupported card or Incorrect format. Please change cards or format card.
100 The AR-200S received a “2Q” or “3Q” command even though the specified
phrase was not a pattern phrase.
101 A “PQ” ,”QQ” or “TQ” command is used to request output even after the
setting information of the last phrase has been output.
202 There is no time information for the specified phrase.
300 The command is not compatible with the Dual Mono mode.
301 Specify a time parameter within the phrase recording time.
302 Phrases other than audio phrases cannot be specified.
304 Phrases other than audio phrases, MIDI phrases, and pattern phrases cannot
be specified.
305 There is no blank phrase.
306 In the Delete mode, only editing commands are processed.
307 Before sending an RL command, first specify a phrase with the PA command.
309 The settings cannot be output, because it is expanded function in AR-200S.
Please use the request command corresponding to AR-200S.
310 To execute the edit operation, transmit “ACK”. To cancel the delete operation,
Transmit “stxER:1”.
311 The AR-200S received a “GQ” command even though the specified phrase was
not a song phrase.
313 The command does not correspond to the selected phrase.
314 The AR-200S received a “PS” command even though the interrupt phrases for
ramdom 2 or 3 are not specified.
315 A card in AR-2000 format was inserted in either slot A or B (or both).
Or the syntax of the command was incorrect or inappropriate.
320 The AR-200S gets hot. Ventilate well to avoid overheating, and keep the unit
cool.
Note: When these commands occur, commands from the external device will be
ignored.
= Xon (11H) / Xoff (13H) Allow or Disable Transmission. Used for Handshaking
Function: Allow or disable transmission. Used for handshaking.
Syntax: Xon is 11H only (transmission permitted)
Xoff is 13H only (transmission disabled)