Owner`s manual

R
AR-200S RS-232C Reference -
33
> SY System Setting Output
Function: System setting output
Syntax: stxSY: a, b, c, d, e, f, g, h, i, j, k, l, m, n, o, p, q, r, s, t, u, v, w, x;
a Reserved (0)
b Control Input select
0 Direct playback
1 Program playback
2 Binary playback
3 Binary REC
4 Interval playback
c Direct playback
0 Normal playback
1 First-In playback
2 Last-In playback
3 Sequence playback
d Binary Playback Trigger
Settings Level
0 Off
1 On
e Binary Playback Trigger
Settings-Edge
0 Off
1 On
f The Method used for specifying
the phrase (Binary Recording)
0 Binary 1
1 Binary 2
g Reserved (0)
h Dual Mono Mode
0 OFF
1 ON
i Line Thru
0 Off
1 On
j Line Thru Volume % ( 0 - 100 )
k Line Thru Fade Out ( 0S5 - 59S9 )
l Line Thru Fade In ( 0S5 - 59S9 )
m Equaizer
0 Off
1 On
n Equalizer Low Gain dB ( -12 - +12 )
o Equalizer Low Frequency
0 200Hz
1 400Hz
p Equalizer High Gain dB ( -12 - +12 )
q Equalizer High Frequency
0 3kHz
1 6kHz
r Equalizer Attenation dB( -12 - 0 )
s Reserved (0)
t Busy Out - During Delay Time
0 Off
1 On
u Busy Out - During Phrase Play
0 Off
1 On
v Busy Out - During Repeat Int
0 Off
1 On
w Reserved (0)
x Reserved (00M30S)
Note: refer to YQ command
= TI Time Stamp Settings
Function: Time Stamp settings
Syntax: stxTI: a, b, c, d, e, f, g;
a Phrase number
b year( 1998 - 2050 )
c month( 1 - 12 )
d day( 1 - 31 )
e hour( 0 - 23 )
f minute( 0 - 59 )
g second( 0 - 59 )
Note: refer to TQ command