Owner`s manual

R
AR-200S RS-232C Reference -
30
> RU Phrase Setting Output
Function: Phrase setting output
Syntax: stxRU: a, ”b”, c, d, e, f, g, h, i, j, k, l, m, n, o, p, q, r, s, t, u, v, w, x, y;
a Phrase number
b Phrase name
(up to 12 characters)
c Phrase type
0 Phrase
1 Pattern Phrase
2 MIDI Phrase
3 Song Phrase
d RDAC-Grade
0 Announce
1 Long 2
2 Long 1
3 Standard
4 High
5 S-High
e RDAC-Mode
0 Linear
1 Mode 1
2 Mode 2
3 Mode 3
4 H-Linear
f Recording Type
0 Mono
1 Stereo
g Playback Volume (10 - 100)
h Delay Time (0S0 - 59S9)
i Repeat Playback
0 OFF
1 ON
j Repeat Count
0 ENDLESS
1 1
| |
99 99
k Repeat interval
(0M0S - 59M59S)
l Control Output
0 (OFF)
1 (ON)
m Offset time of control output (0M0S -
59M59S)
n Fade In Type
0 OFF
1 Time 1
2 Time 2
3 Time 3
4 ( 0S1 - 59S9 )
o Fade In Time ( 0S1 - 59S9 )
p Fade Out Type
0 OFF
1 Time 1
2 Time 2
3 Time 3
4 ( 0S1 - 59S9 )
q Fade Out Time ( 0S1 - 59S9 )
r Start
(0H0M0S0F0S - 23H59M59S**F9S)
s End
(0H0M0S0F0S - 23H59M59S**F9S)
t Loop Play
0 (OFF)
1 (ON)
u The number of loops
0 ENDLESS
1 1
| |
99 99
- Loop play Off
v Loop 1 position
(0H0M0S0F0S - 23H59M59S**F9S)
w Loop 2 position
(0H0M0S0F0S - 23H59M59S**F9S)
x Tempo (5 - 260)
y Phrase size (unit: byte)
Note: refer to QQ command
The number of digits for **F (frame) increases according to the value of MTC
type.