Owner`s manual

R
AR-200S RS-232C Reference -
20
= CE Program(Count) Playback Settings
Function: Program (Count) Playback setting
Syntax: stxCE: a, b, c, c, .... , c;
a Reserved (0)
b Program Playback pattern( 1 - 5 )
c Phrase number to be played back (up to 100 phrases)
Example) CE:0,1,A1,A2,A3,A4,A5;
This registers A0001,A0002,A0003,A0004,and A0005 into the Program Playback
pattern 1.
= DP Direct Playback Settings
Function: Direct Playback setting
Syntax: stxDP:a, b, c, .... , j;
a Reserved (0)
b - j Phrase number which you wish to assign to control input pin
b (CH1)
c (CH2)
|
j (CH9)
Example) DP:0,A1,_,A3,A4,_,A9;
The setting will be written to Card, and the phrases will be assigned to the control
input pin as follows; A0001 to CH1,...,A0003 to CH3, A0004 to CH4,..., and A0009 to
CH9.
Note: For unused direct channels, specify “----”.
If you specify “PLAY” instead of a phrase, you can playback directly the phrase
shown in the display by the control input pin.
> DL Direct Playback Settings
Function: Direct Playback setting
Syntax: stxDL: a, b, c, .... , j, k;
a Reserved (0)
b - j Phrase number which you wish to assign to control input pin
b (CH1)
c (CH2)
|
j (CH9)
k Direct Playback Method
0 Normal playback
1 First-In playback
2 Last-In playback
3 Sequence playback
Example) DL:0,A1,_,A3,A4,..,A9,0;
The setting will be written to Card, and the phrases will be assigned to the control
input pin as follows; A0001 to CH1,...,A0003 to CH3, A0004 to CH4,..., A0009 to CH9,
Direct Playback “Normal playback”.
Note: For unused direct channels, specify “----”.
If you specify “PLAY” instead of a phrase, you can playback directly the phrase
shown in the display by the control input pin.
Caution Direct Playback Settings data will not be written to card.