Owner`s manual

R
AR-200S RS-232C Reference -
17
Phrase Settings
< SU Phrase Settings
Function: Phrase settings
Syntax: stxSU: a , “b” , c, d, e, f, g, h , i, j;
a Phrase number
b Phrase name (up to 12 characters)
c Playback Volume (10 - 100)
d Delay Time (0S0 - 59S9)
e Repeat Playback
0 OFF
1 ON
f Repeat interval (0M0S - 59M59S)
g Control Output
0 OFF
1 ON
h Offset time of control output (0M0S - 59M59S)
i Tempo (5 - 260)
j Reserved (0)
Example) SU:A001,“ABCDEFGHIJK”,100,10S5,1,5M0S,1,5M10S,120,0;
For phrase number “A001”, this sets as follows; Phrase name “ABCDEFGHIJK”,
Playback Volume “100%”, Delay Time “10.5 seconds”, Repeat Playback “ON”, Repeat
interval “5 minutes”,
Control Output “ON”, Offset time of control output “5min10sec”, and Tempo “120”.
Note: Be sure to specify an already recorded phrase as the phrase number.
> PN Phrase Name Settings
Function: Phrase Name settings
Syntaxs stxPN: a, “b”;
a Phrase number
b Phrase name (up to 12 characters)
> PR Phrase Repeat Settings
Function: Phrase Repeat settings
Syntax: stxPR: a, b, c, d;
a Phrase number
b Repeat
0 OFF
1 ON
c The number of repetitons
0 ENDLESS
1 1
| |
99 99
d Repeat interval (0M0S - 59M59S)
> PO Control Out Settings
Function: Control Out settings
Syntax: stxPO: a, b, c;
a Phrase number
b Control Out
0 OFF
1 ON
c Offset Time (0M0S - 59M59S)